+91 9004 104 717  |  Mon–Sat: 09:00 AM–06:00 PM sales@kunchamcontrols.com
Industrial instrumentation

Differential Pressure Transmitter Manufacturer in India

Differential pressure (DP) transmitters for flow measurement, filter and strainer pressure-drop monitoring, HVAC air / duct pressure and closed-tank level applications. Select local indication, 4-20 mA transmission and communication options according to the process duty.

2 product families Complete specifications
Product range

Explore Our Differential Pressure Transmitters

Differential Pressure Indicator Transmitter
KCDPIT Series (KCPTX-S)

Differential Pressure Indicator Transmitter

Differential Pressure Indicator Transmitters are designed for accurate measurement, local indication and remote transmission of pressure difference across filters, flow elements, tanks and process equipment.

  • 5-digit backlit LCD for clear local indication
  • Positive, negative and bidirectional differential-pressure measurement
View product
Mini Differential Pressure Transmitter, standard
KCMDPT Series (KCPL-PTXM-S-LCD)

Mini Differential Pressure Transmitter

Mini Differential Pressure Transmitters are designed for compact and reliable measurement of differential pressure in industrial, OEM and skid-mounted applications where installation space is limited.

  • Compact differential-pressure transmitter for space-limited installations
  • Suitable for positive and negative differential-pressure measurement
View product
Overview

Product Description

Differential pressure transmitters measure the difference between two pressure points rather than a single process pressure. Kuncham instruments are used for filter condition monitoring, flow measurement across a primary element, closed-tank level and other applications where the pressure difference is the required process value.

The range includes a full-size Differential Pressure Indicator Transmitter with a backlit display and communication options, plus a compact Mini Differential Pressure Transmitter for OEM equipment, HVAC, clean-room and space-limited process installations.

How it works

Working Principle

High-side and low-side process pressures act on the sensing element. The common pressure is rejected and the difference between the two inputs is converted into the measured differential-pressure signal.

01

Two pressure inputs

The high-pressure and low-pressure sides are connected to the two process points being compared.

02

Difference measurement

The sensing element responds to the pressure difference while common pressure is compensated by the measuring arrangement.

03

Process output

Electronics condition the signal for local indication and/or 4-20 mA transmission to the control system.

At a glance

Key Highlights

  • Indicator and compact Mini Differential Pressure Transmitter options
  • Differential-pressure ranges from 50 mmWC to 25 bar and higher on request
  • Static pressure up to 50 bar and higher on request on the indicator model
  • Multiple accuracy options down to ±0.075% on the indicator model
  • 4–20 mA output with HART / RS485 Modbus RTU on the indicator model
  • SS304 / SS316 / SS316L / Hastelloy C / Tantalum / PTFE-coated material options by configuration
Range summary

Technical Specifications

Values below summarise the product family. Open an individual product for its complete model and variant data.

Product Types
Differential Pressure Indicator Transmitter / Mini Differential Pressure Transmitter
Differential Pressure Range
0–50 mmWC to 0–25 bar; higher ranges on request
Static Pressure
Up to 50 bar; higher on request on indicator model
Accuracy
±2% / ±0.5% / ±0.25% / ±0.075%, according to model/range
Output
4–20 mA
Communication
HART / RS485 Modbus RTU on indicator model
Process Connection
Threaded / manifold / flanged / compact direct mounting
Wetted & Diaphragm Materials
SS304 / SS316 / SS316L / Hastelloy C / Tantalum / PTFE-coated, according to configuration
Indicator Enclosure
Flameproof, IP67 / Ex d IIC T6 Gb
Typical use

Applications

  • Filter differential-pressure monitoring
  • Closed and pressurised tank level
  • Flow measurement across primary elements
  • HVAC and clean-room pressure monitoring
  • Pump and process monitoring
  • OEM equipment and compact skids
Selection confidence

Why Choose Kuncham Controls?

Purpose-built selection

Choose a display-based transmitter for process indication or a compact model for OEM and space-limited installations.

Multiple DP duties

One product family supports filter, flow, level, HVAC and general differential-pressure monitoring duties.

Integration options

Industrial outputs and communication choices support connection to PLC, DCS, SCADA and local control panels.

Process configuration support

Kuncham assists with range, direction, connection, remote seals, wetted material and output selection.

Support

Questions & Answers

What is a differential pressure transmitter?

It measures the pressure difference between a high-pressure input and a low-pressure input and converts that difference into a local indication and/or electrical output.

Which model is suitable for filter monitoring?

Both families can be selected for filter monitoring. The indicator model suits installations needing local display and communication; the mini model suits compact OEM and low-space installations.

Can differential pressure be used for level measurement?

Yes. A differential pressure transmitter can measure level in a closed or pressurised tank by compensating the vessel pressure and measuring the liquid-column contribution.

Can it be used for flow measurement?

Yes. Differential pressure across an orifice plate or another primary element can be converted to flow, with square-root output available on selected indicator models.

What details are required for selection?

Provide the differential range, static pressure, process media, temperature, connection, mounting, wetted material, output and whether display or communication is required.

Scroll