Industrial temperature transmitters for PT100 / RTD process measurement with 4-20 mA output, local LCD indication and communication options. Choose field-mounted temperature indicator transmitters, compact head-mounted transmitters or a transmitter with remote process indicator.
Temperature Indicator Transmitters are designed for continuous temperature measurement with clear local indication and remote signal transmission in industrial process applications.
Local LCD indication for real-time temperature monitoring
Head-Mounted Temperature Transmitters are designed for compact temperature signal transmission directly from the sensor head in industrial process applications.
Compact head-mounted design for industrial temperature measurement
Temperature Transmitter with Process Indicator is a complete temperature measurement solution combining a field-mounted temperature sensor/transmitter with a separate digital indicator for remote panel indication.
Complete temperature measurement with remote process indication
Kuncham Controls temperature transmitters convert signals from industrial temperature sensors into stable 4-20 mA outputs for PLC, DCS, SCADA and control-panel monitoring. The range includes instruments with local indication, compact head-mounted conversion and a panel-mounted process indicator.
Temperature Indicator Transmitters provide field indication and communication in a rugged enclosure. Head-Mounted Temperature Transmitters fit inside the sensor connection head to condition the signal close to the measuring point, while the Process Indicator provides a clear remote reading at the control panel.
How it works
Working Principle
An RTD or compatible temperature sensor changes its electrical signal as process temperature changes. The transmitter linearises and conditions this signal, then converts it into a standard current output for indication and control.
01
Temperature sensing
A PT-100, PT-1000 or compatible sensor detects the process temperature at the selected insertion point.
02
Signal conditioning
The transmitter amplifies, linearises and compensates the low-level sensor signal for stable industrial measurement.
03
Indication and transmission
The measured value is shown locally or remotely and transmitted as 4-20 mA, with HART or RS-485 available on selected models.
At a glance
Key Highlights
PT100 / PT1000 RTD and thermocouple input options
Temperature range from -50°C to 600°C
Full-size Temperature Indicator Transmitter with flameproof IP67 / Ex d IIC T6 Gb enclosure
Compact Head-Mounted Temperature Transmitter with 4–20 mA, 2-wire output
Separate 4-digit panel LCD option with Temperature Transmitter with Process Indicator
Threaded, flanged, Tri-Clover and thermowell configurations according to model
Range summary
Technical Specifications
Values below summarise the product family. Open an individual product for its complete model and variant data.
Product Types
Temperature Indicator / Head-Mounted Temperature Transmitter / Temperature Transmitter with Process Indicator
Sensor Input
PT100 / PT1000 RTD / Thermocouple
Temperature Range
-50°C to 600°C
Accuracy
±1% FSD standard; higher accuracy available on request
Output
4–20 mA; 1–5 V / 2–10 V additionally available on Temperature Indicator Transmitter
Communication
HART / RS485 Modbus RTU on Temperature Indicator Transmitter
Process Indicator
Separate 4-digit LCD on panel-indicator system
Probe Materials
SS304 / SS316 / SS316L
Indicator Enclosure
Flameproof, IP67 / Ex d IIC T6 Gb on full-size indicator model
Typical use
Applications
Furnaces and boilers
Chemical reactors and process vessels
Steam and hot-oil lines
Food and pharmaceutical processing
Power generation and utilities
HVAC, process skids and control panels
Selection confidence
Why Choose Kuncham Controls?
Three installation formats
Select local field indication, compact head-mounted conversion or remote panel indication to suit the installation.
Control-system ready
Standard 4-20 mA output and communication options simplify integration with PLC, DCS and SCADA systems.
Flexible mechanical selection
Multiple process connections, probe lengths and mounting arrangements support varied plant layouts.
Application-based support
Kuncham helps match the sensor, range, connection, probe, enclosure, output and indication requirement to the process.
Support
Questions & Answers
Which temperature transmitter should I choose?
Choose the Temperature Indicator Transmitter when a local display and field communication are required, the Head-Mounted Temperature Transmitter for compact conversion at the sensor head, or the Process Indicator for remote control-panel viewing.
Which temperature sensors are supported?
The centralized range specifies PT-100 and PT-1000 RTD inputs. Compatible sensor options can be selected according to the transmitter model and application.
What output signals are available?
The range supports 4-20 mA two-wire output with HART. Optional RS-485 Modbus is available on selected configurations.
Are different process connections and probe lengths available?
Yes. Screwed and flanged connections are available, and probe length can be customised for the insertion depth and process arrangement.
What information is needed for selection?
Provide the temperature range, sensor type, process media, insertion length, process connection, mounting, enclosure, output, communication and display requirements.