+91 9004 104 717  |  Mon–Sat: 09:00 AM–06:00 PM sales@kunchamcontrols.com

Flame Arresters

Model No: KCPL-FA Series

Flame Arresters are designed to prevent flame propagation through pipelines, vent lines and storage-tank breathing systems handling flammable gases or vapours.

The arrester uses a crimped ribbon or bird-mesh element to absorb and dissipate flame energy, helping stop the flame front from travelling further through the system.

Available in inline, end-of-line and breather-valve-combined configurations, the product can be supplied in multiple sizes, body materials and element materials. Carbon-steel, stainless-steel and PTFE-coated body options are available, with SS304, SS316 and Hastelloy C-276 flame-arresting elements for different process requirements.

Flame Arrester
Flame Arrester
Download Brochure
Key Specifications
  • Crimped ribbon and bird-mesh element options
  • Inline and end-of-line installation configurations
  • Sizes from 1″ (DN25) to 20″ (DN500)
  • Design temperature up to 350°C
  • Carbon steel, stainless steel and PTFE-coated body options
  • SS304 / SS316 / Hastelloy C-276 element material options
Technical Specifications
Size
1″ (DN25) to 20″ (DN500)
End Connection
Flanged / Threaded / Tri-Clover
Body MOC
A216 WCB / CF8 / CF8M / CF3 / CF3M / PTFE-coated
Element Type
Crimped Ribbon / Bird Mesh
Element MOC
SS304 / SS316 / Hastelloy C-276
Design Pressure
Up to 15 barg
Design Temperature
Up to 350°C
Pressure Rating
Class 150; higher ratings available on request
Find Applications
  • Storage tank vent and breather lines
  • Fuel, solvent and hydrocarbon vapour lines
  • Chemical and petrochemical process systems
  • Biogas and combustible gas pipelines
  • Ventilation lines handling flammable vapours
  • Protection of equipment from flame propagation
  • End-of-line venting and inline flame protection

Types of Flame Arresters We Manufacture

Select Explore specifications to view that configuration's data in a popup.

Inline Flame Arrester

Inline Flame Arrester

KCPL-FA-IL

Installed within the pipeline to stop flame propagating from the exposed side to the protected side.

End-of-Line Flame Arrester

End-of-Line Flame Arrester

KCPL-FA-EL

Fitted at the end of the vent line to stop atmospheric flame propagation before it enters the storage system.

Breather Valve cum Flame Arrester

Breather Valve cum Flame Arrester

KCPL-FA-BRVL

Combines pressure/vacuum relief with flame quenching in one unit: the breather valve regulates air flow while the arrester stops flame entering the tank.

Scroll